APC InRow RD, 600mm Air Cooled, 380-415V, 50/60Hz

Regular price $37,738.30
Sale price Regular price

Key specifications

  • Product colour: Black

Packaging data

Package depth
113.7 cm
Package height
216.6 cm
Package weight
436 kg
Package width
85 cm

Weight & dimensions

Depth
107 cm
Height
199.1 cm
Weight
391 kg
Width
60 cm

THE NUTEC ADVANTAGE

VENDOR NEUTRAL

Advice focused on the solution that best fits your business needs.

END TO END DELIVERY

From selection through implementation, support, and beyond.

BUSINESS FIRST OUTCOMES

Delivering solutions focused on measurable outcomes.

LONG TERM PARTNERSHIP

Built on trust, support, and shared success.

Compare With Similar Items

Description
Active Airflow Control
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.

Active response control
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.

Air filtration
Removes dirt and other particulates from the intake air for cleaner supply air.

Architecturally neutral
Unobtrusive design and coloring, blends in with the surroundings.

Capacity Control
Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.

Casters
Provides flexibility to move the unit to wherever cooling is required.

Containment system compatible
The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency

Continuous current monitoring
Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).

Direct drive motors
Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

Ease of Use
Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.

Easy to install
Innovative design allows for fast, easy installation by almost anybody.

Efficiency
Increases the capacity of the air conditioner by supplying a warmer return air temperature.

Electric Reheat
Prevents overcooling during dehumidification.

Electronic expansion valve
Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring

Electronically Commutated Fans
Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.

Enclosure system compatible
Specifically designed to work with Netshelter Enclosures.

Fan guards
A safety measure that provides protection from the fan opening by covering the inlet.

Fault-tolerant fan system
In the event of a fan failure, the remaining fan(s) will continue to operate.

Field replaceable components
Fans and electronics module can be readily replaced without uninstalling the unit.

Flexibility
Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment

Front service access
The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.

Green Refrigerant
Environmentally friendly refrigerant that can offer LEED points.

Hardwire capable
For installations where hard wiring is required or prefered.

Head pressure control
Modulates refrigerant head pressure to protect from coil freeze.

High Sensible-to-Total Cooling Ratio
Achieved by careful sizing of heat exchanger coils.

Horizontal airflow pattern
Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.

Humidifier
Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.

Increased capacity
Higher rate of heat removal allows more equipment to be installed in each rack.

Local area network
Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations

Minimizes Air Mixing
Delivers cool, conditioned air directly to the inlet of IT equipment.

Modular strategy
Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.

Network interface
Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.

Operational efficiency
Warmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.

Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Predictive failure notification
Maximizes system availability by providing early warning of required fan or filter replacement.

Programmable input/output contacts
Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.

Rack Inlet Temperature Control
Reduces the risk of hot spots at the rack level

Real-Time Capacity Monitoring
Real-time display of current and available cooling.

Rear containment
Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Scalable Design
Modular design provides scalable solutions to add cooling as demand increases.

Small Footprint
Efficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.

Temperature Display
Monitors and displays temperature to prevent overheating.

Touch-screen GUI
Enables easy configuration, full monitoring, and event logging
"The Easy Rack Fan Tray is a low cost solution that aids in heat removal from an Easy Rack" "The fan tray could be easily installed into the rear door and precisely expels heat from the rear of the rack" "The fan tray is designed to promote front to rear airflow within the rack"
Active Airflow Control
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.

Active response control
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.

Air filtration
Removes dirt and other particulates from the intake air for cleaner supply air.

Architecturally neutral
Unobtrusive design and coloring, blends in with the surroundings.

Capacity Control
Cooling system will operate from 0 - 100% of the rated capacity to maintain rack inlet temperatures and reduce operational costs at varying heat loads.

Casters
Provides flexibility to move the unit to wherever cooling is required.

Containment system compatible
The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency

Continuous current monitoring
Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).

Direct drive motors
Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

Ease of Use
Simplifies future planning by allowing side to side equipment to be placed anywhere in the data center.

Easy to install
Innovative design allows for fast, easy installation by almost anybody.

Efficiency
Increases the capacity of the air conditioner by supplying a warmer return air temperature.

Electric Reheat
Prevents overcooling during dehumidification.

Electronic expansion valve
Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring

Electronically Commutated Fans
Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.

Enclosure system compatible
Specifically designed to work with Netshelter Enclosures.

Fan guards
A safety measure that provides protection from the fan opening by covering the inlet.

Fault-tolerant fan system
In the event of a fan failure, the remaining fan(s) will continue to operate.

Field replaceable components
Fans and electronics module can be readily replaced without uninstalling the unit.

Flexibility
Support for varying aisle widths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment

Front service access
The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.

Green Refrigerant
Environmentally friendly refrigerant that can offer LEED points.

Hardwire capable
For installations where hard wiring is required or prefered.

Head pressure control
Modulates refrigerant head pressure to protect from coil freeze.

High Sensible-to-Total Cooling Ratio
Achieved by careful sizing of heat exchanger coils.

Horizontal airflow pattern
Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.

Humidifier
Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.

Increased capacity
Higher rate of heat removal allows more equipment to be installed in each rack.

Local area network
Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations

Minimizes Air Mixing
Delivers cool, conditioned air directly to the inlet of IT equipment.

Modular strategy
Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expeditures and provides deferred investment throughout the life of the facility.

Network interface
Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.

Operational efficiency
Warmer entering air temperatures reduce both the required amount of humidification and the demand for costly reheat.

Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Predictive failure notification
Maximizes system availability by providing early warning of required fan or filter replacement.

Programmable input/output contacts
Allows device contacts to be connected to the air conditioner and mapped to customer outputs or system alarms.

Rack Inlet Temperature Control
Reduces the risk of hot spots at the rack level

Real-Time Capacity Monitoring
Real-time display of current and available cooling.

Rear containment
Ensures server exhaust air is returned to the InRow cooling units for maximum cooling predictability.

Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Scalable Design
Modular design provides scalable solutions to add cooling as demand increases.

Small Footprint
Efficient use of space with a small footprint provides the ability for the unit to be placed in a corner or even installed into a partitioned space.

Temperature Display
Monitors and displays temperature to prevent overheating.

Touch-screen GUI
Enables easy configuration, full monitoring, and event logging
Availability
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Rack Inlet Temperature Control
Reduces the risk of hot spots at the rack level

Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.

In-Row architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Agility
Modular design
Modular design provides scalable solutions to add cooling as demand increases.

Scaleable densities
Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
InRow RC, 600mm, Chilled Water 380-415V 50/60 Hz, w/ humidifier
Price
Regular price $37,738.30
Sale price Regular price
Regular price $210.81
Sale price Regular price
Regular price $58,197.35
Sale price Regular price
Regular price $24,766.23
Sale price Regular price
Regular price $56,078.18
Sale price Regular price
Product variants

Special Offer

FREE SHIPPING ON ORDERS OVER $550 IN SELECTED AREAS

Explore our FAQ

Contact Us

Where do the specifications come from?

Product specifications are sourced from Icecat and displayed only when supporting data is available. Where information is missing, the field is left blank rather than populated with estimated or inferred values.

A Partnership-First Approach

At NUTEC, we take a partnership-first approach to every engagement. We start by understanding your business - its challenges, priorities, and long-term goals before recommending any technology solution. From workplace modernization and cloud infrastructure to cyber security and systems integration, our team works closely with you at every stage, ensuring the right technology is procured, implemented, and supported with clarity and confidence. We believe in transparent communication, tailored outcomes, and building lasting partnerships that grow with your business.

Support Hours

Mon–Fri, 9am–5pm AEST

Phone

0401 113 232

Email

sales@nutec.com.au

Address

Online Store