Key specifications

  • Product colour: Black
  • AC outlets quantity: 42 AC outlet(s)
  • PDU types: Metered
  • Rack capacity: 0U
  • AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler
  • Nominal input voltage: 400 V
  • Operating temperature (T-T): 23 - 140 °F
  • AC input frequency: 50 - 60 Hz
  • Maximum current: 16 A
  • Mounting: Vertical
  • Operating relative humidity (H-H): 5 - 95%
  • Storage relative humidity (H-H): 5 - 95%
  • Power plug: IEC 60309
  • Nominal output voltage: 230 V
  • Compliance certificates: RoHS
  • Type: Three-phase
  • Operating altitude: 0 - 3048 m
  • Maximum power: 11040 W
  • Total carbon footprint (kg of CO2e): 8717.32
  • Non-operating altitude: 0 - 15240 m

Design

Display
LCD
Form factor
Rackmount
On/off switch
Yes
Regulatory Approvals
CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1

Features

Cable length
1.8 m
Colour-coded outlets
Yes
Compatible products
Compatible with most NetShelter SX\nenclosures and third-party racks
Daisy chain
Yes
LED indicators
Activity, Network, Power
Password protection
Yes
Reset button
Yes
Security algorithms
128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3

Management features

Firmware upgradeable
Yes
Firmware upgradeable via
Network, USB
Monitoring
Current, Humidity, Power, Temperature, Voltage
Outlet control
Lock-out, Recycle, Turn on

Operational conditions

Storage temperature (T-T)
-25 - 65 °C

Packaging data

Package depth
11.6 cm
Package height
172 cm
Package weight
7.7 kg
Package width
20.8 cm

Ports & interfaces

Ethernet LAN (RJ-45) ports
2
USB ports quantity
1

Power

Load capacity
11500 VA
Maximum total current draw per phase
16 A
Number of phases
3
Output voltage
230 V
Power protection features
Overload
Surge protection
Yes

Weight & dimensions

Depth
5.5 cm
Height
149 cm
Weight
5.7 kg
Width
5.6 cm

THE NUTEC ADVANTAGE

VENDOR NEUTRAL

Advice focused on the solution that best fits your business needs.

END TO END DELIVERY

From selection through implementation, support, and beyond.

BUSINESS FIRST OUTCOMES

Delivering solutions focused on measurable outcomes.

LONG TERM PARTNERSHIP

Built on trust, support, and shared success.

Compare With Similar Items

Description
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Remote Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.


Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Power Delays

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
Toolless Rack Mounting Capabilities

Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.

Vertical Mounting Capabilities

Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

Wide range of input and output connections

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Single input power source

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable

Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Remote Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Price
Regular price $2,276.44
Sale price Regular price
Regular price $2,217.14
Sale price Regular price
Regular price $1,899.26
Sale price Regular price
Regular price $1,643.87
Sale price Regular price
Regular price $1,078.41
Sale price Regular price
Product variants

Special Offer

FREE SHIPPING ON ORDERS OVER $550 IN SELECTED AREAS

Explore our FAQ

Contact Us

Where do the specifications come from?

Product specifications are sourced from Icecat and displayed only when supporting data is available. Where information is missing, the field is left blank rather than populated with estimated or inferred values.

A Partnership-First Approach

At NUTEC, we take a partnership-first approach to every engagement. We start by understanding your business - its challenges, priorities, and long-term goals before recommending any technology solution. From workplace modernization and cloud infrastructure to cyber security and systems integration, our team works closely with you at every stage, ensuring the right technology is procured, implemented, and supported with clarity and confidence. We believe in transparent communication, tailored outcomes, and building lasting partnerships that grow with your business.

Support Hours

Mon–Fri, 9am–5pm AEST

Phone

0401 113 232

Email

sales@nutec.com.au

Address

Online Store